The sitting tasks included sitting on an Automatic Abs air-cushio

The sitting tasks included sitting on an Automatic Abs air-cushion (Licensing Services International Inc.,

Philadelphia, PA, USA), a stability ball (Cando®; Fabrication Enterprises Inc., White Plains, NY, USA), or an immobile surface (chair) for a duration of 30 min each while kinematic and ground reaction force data were collected. A 5-min break was offered between each sitting condition. The immobile surface condition required participants to sit on a wooden box 40 cm in height without a backrest. In the air-cushion condition, the participants sat on the same wooden box with an Automatic Abs air-cushion placed on top. The Automatic Abs air-cushion was an air-filled cushion 30.5 cm in diameter

and 5 cm thick. During ERK inhibitor the stability ball condition, the participant sat on a stability ball 177 cm in circumference. The sitting posture was standardized for all participants. For each condition, participants XAV-939 nmr were instructed to place each foot on a separate force plate. Participants remained seated with an upright trunk, their hands resting on their thighs, and their knees flexed at 90° during data collection. For the duration of each trial, the participants viewed a 52-inch flat screen television 20 feet away which displayed a television show at approximately eye level. All participants wore compression shirts and shorts and were barefoot during testing. Anthropometric measurements were taken of each participant, including height, weight, leg length, anterior superior iliac spine and posterior superior iliac spine distances, ankle, knee and wrist width, shoulder offset, and hand thickness. Thirty-two retro-reflective markers (diameter = 14 mm) were placed on the participant using a modified Plug-in-Gait model with additional makers placed over the fifth metatarsal head, the sacrum, and the superior rim of the side of the iliac crest. Past research had examined and verified the validity of the Plug-in-Gait protocol in a gait laboratory much setting.12 and 13 To ensure reliability of the experiment, an experienced researcher (KW) was designated

to perform subject measurements and marker placements for all the participants. Posture was monitored by 12 Vicon MX-40 infrared cameras sampling at 60 Hz (Vicon; Oxford Metrics, Oxford, UK). The Vicon system tracked the position of the reflective markers in space for the duration of each trial. Ground reaction forces at the feet were collected using two AMTI OR6-7 force plates (Advanced Mechanical Technology Inc., Watertown, MA, USA) sampling at 600 Hz by placing one foot on each force plate. Data were processed using Vicon Nexus v.1.7 and the biomechanical variables were calculated using Visual 3D v.4.9 (C-motion Inc., Germantown, MD, USA). Trunk angle, trunk center of mass, and center of pressure were measured for each sitting trial.

Comments are closed.